Bronx Mount Hope
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
21 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Jul 29, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO COMPLY W/COMMISSIONER'S ORDER #356764(112020FEU20508XC) DATED 11/20/2020 REQUIRING OWNERSHIP TO PERMANENTLY REPAIR THE RETAINING WAL UNDER PERMIT,STRTNG BY 02/01/2021.AS OF 07/29/2026,NO WORK PERMIT TO REPAIR THE RETAINING WALL HAVE BEEN OBTAIND.IMMEDIATELY COMPLY W/COMMISSIONER'S ORDER #356764(112020FEU20508XC)DATED 11/20/20 |
| Jul 29, 2026 | V-DOB VIOLATION - ACTIVE | EGNCY-EMERGENCY NONE | REMEDY: FULLY DEMOLISH THE BUILDING AT 1760 ANTHONY AVENUE, BRONX GRADE AND FENCE SITE |
| Jul 29, 2026 | V-DOB VIOLATION - ACTIVE | EGNCY-EMERGENCY NONE | REMEDY: FULLY DEMOLISH THE BUILDING AT 1760 ANTHONY AVENUE, BRONX ENCE SITE |
| Nov 14, 2025 | V-DOB VIOLATION - ACTIVE | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION |
| May 8, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | UNLAWFUL ACTS.FAIL TO COMPLY W/COMMISSIONE ORDER 081524CRW20501BH ISSU 8/15/2024. NO PERMITS OBTAINED TO REPAIR STRUCTURALLY COMPROMISED RW REMEDY:IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDER 081524CRW20501BH ISSUED ON 8/15/2025. RW UNIT, 280 BROADWAY, NEW YORK, NY 10007. ATT: BILL HALKADAKIS, P.E |
| Aug 15, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMERGENCY WORK & STABILIZATION. THE REAR OF BUILDING (EXPOSURE #3) IS STRUCTURALLY UNSTABLE DUE TO PREVIOUS COLLAPSE OF A RETAINING WALL ALONG THE READ CORNER OF BUILDING ALONG THE SOUTHEAST CORATER HAS FAILED & COULD COLLAPSE AT ANY TIME.REMEDY: IMMEDIATELY RETAIN A STRUCTURAL ENGINEER WITH DEMO/STABLIZATION NO LATER THAN 9/15/2024 |
| Jan 29, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | STRUCTURE RENDERED NON-COMPLIANT. A PARTIAL VACATE HAS BEEN SISSSUED O N 11-23-20 TO A VACANT MULTIPLE DWELLING IN WHICH THE REAR OF THE BUIL DING EXHIBITS STRUCTURAL DISREPAIR & SIGNS OF SIGNIFICANT MOVEMENT WI TH POTENTIAL OF COLAPSE. THE RETAINING WALL @ EXPOSUE 3 IS STRUCTALLY UNSAFE WITH POTENTIAL OF FURTHER COLLAPSE |
| Jan 10, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | RETAINING WALL BETWEEN ANTHONY AVE AND CARTER AVE APPROXIMATELY OVER 150'-0" COLLAPSED. SECTION OF RETAINING WALL COLLAPSED ONTO CAR REPAIR SHOP AND DAMAGED REAR ROOF & WALL. |
| Apr 25, 2023 | V-DOB VIOLATION - ACTIVE | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION |
| Nov 20, 2020 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FTM:2 STORY+BSMT MASN WALLS WOOD FRAME FLRS RESID BLDG.REAR WALL SHOWS SIGNS&MOVEMT &CRACKS WERE OBSERVD @SOUTH EAST CORNR.SLAB ON GRADE@REAR HAS SETTLED.RETAIN WALL@REAR PROP LINE IN STATE DISRPR&BULG POTENT OF COLLAPSE.OWNER TO ENGAGE NYSPE TO EVALU THE BLDG&SUBMIT MONTHLY REPTS REPR BLDG&RETAIN WALL UNDER PERMIT.FILE BY 1/15/21.START WRK BY 2/1/21 |
| Nov 16, 2020 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDINGS IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED, VARIOUS CRACKS IN FOUNDATION WALLS AT EXPOSURE # 3 & 4 OF BOTH INSIDE & OUTSIDE, HALF INCH DEEP CRACKS ARE SEPARATE FROM CELLING AT INSIDE AND OUTSIDE ALSO AS SAME. |
| Apr 6, 2018 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT |
| Sep 20, 2017 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Jan 1, 2009 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 13, 2004 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 7, 2000 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 29, 1995 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 9, 1994 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| May 17, 1993 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jul 22, 1992 | V*-DOB VIOLATION - DISMISSED | UB-UNSAFE BUILDINGS NONE | UB-UNSAFE BUILDINGS NONE |
| Jul 22, 1992 | V-DOB VIOLATION - ACTIVE | UB-UNSAFE BUILDINGS NONE | UB-UNSAFE BUILDINGS NONE |