Bronx Mount Eden-Claremont (West)
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 2-02792-0014), so they can include other buildings on the same lot.
2473 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Jan 31, 2016 | B | VIOLATION CLOSED | 2G | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTH |
| Jan 31, 2016 | B | VIOLATION CLOSED | 2G | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT NORTH WALL AT WATER CLOSET IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTH |
| Jan 31, 2016 | B | VIOLATION CLOSED | 1E | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTH |
| Jan 31, 2016 | B | VIOLATION CLOSED | 1E | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTH |
| Jan 29, 2016 | A | VIOLATION CLOSED | BB | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT BB, 1st STORY, APARTMENT AT NORTH , SECTION AT SOUTH |
| Dec 29, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR AT PUBLIC HALL, 6th STORY |
| Dec 29, 2015 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT BULKHEAD , SECTION AT SOUTH |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL CEILING AT BULKHEAD , SECTION AT SOUTH |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT SKYLIGHT AT BULKHEAD , SECTION AT SOUTH |
| Dec 29, 2015 | A | VIOLATION CLOSED | Not available | § 62 M/D LAW REARRANGE TELEVISION AND/OR RADIO ANTENNA TO BE AT LEAST 10 FEET ABOVE ROOF AND NOT ATTACHED TO ANY FIRE ESCAPE OR SOIL OR VENT LINE EAST/SOUTH AT ROOF |
| Dec 29, 2015 | A | VIOLATION CLOSED | Not available | § 62 M/D LAW REARRANGE TELEVISION AND/OR RADIO ANTENNA TO BE AT LEAST 10 FEET ABOVE ROOF AND NOT ATTACHED TO ANY FIRE ESCAPE OR SOIL OR VENT LINE AT NORTH/WEST AT ROOF |
| Dec 29, 2015 | A | VIOLATION CLOSED | Not available | § 27-2026 ADM CODE PROVIDE A SUITABLE STRAINER FOR THE DRAIN CENTER ROOF |
| Dec 29, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CABLE WIRES THRU OUT AT ROOF |
| Dec 29, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF REMOVED DUMBWAITER SHAFT WITHOUT PERMIT AT ROOF WEST |
| Dec 29, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT CRACK AT EAST BRICK WALL BETWEEN 3RD AND 6TH STORY WEST YARD |
| Dec 29, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MAKE SHIFT HOIST WITH 4X4 WOOD BEAM EXTENDED ACROSS PARAPET WALL AT ROOF WEST |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE TOP RETURN RAILING LANDING TO ROOF WEST AT FIRE ESCAPE |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING TERRACOTTA COPING PARAPET WALL WEST AT ROOF |
| Dec 29, 2015 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND ALL WALLS AT BULKHEAD TO ROOF , SECTION AT SOUTH |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND ALL WALLS AT BULKHEAD TO ROOF , SECTION AT SOUTH |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING HANDLE AT LOWER SASH WINDOW INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, 3rd STORY, SECTION AT SOUTH |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING AT WEST * YARD |
| Dec 29, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNRESTRAINED DOG (PIT-BULL ) PREVENTING EGRESS FROM FIRE ESCAPE AT WEST YARD |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ERODED MORTAR JOINS AT BRICK WORK BETWEEN 2ND AND 3RD STORIES AT WEST YARD |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE HOUSE HOLD ARTICLES AT WEST YARD |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES EAST WALL AT WEST YARD |
| Dec 29, 2015 | A | VIOLATION CLOSED | Not available | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD STORAGE SHED ERECTED AT WEST INNER COURT ( BY USING STUDS AND PLYWOOD ) APPROX: 3' X 6'* |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING HANDLE AT LOWER SASH WINDOW INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, 1st STORY, SECTION AT NORTH |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT UPPER SASH WINDOW INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, 1st STORY, SECTION AT NORTH |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WIRE GLASS AT UPPER SASH WINDOW INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, 1st STORY, SECTION AT NORTH |
| Dec 29, 2015 | A | VIOLATION CLOSED | Not available | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF PLYWOOD ENCLOSURE INSTALLED UNDER SOFFIT * AT PUBLIC HALL STAIRS, 1st STORY, SECTION AT NORTH |
| Dec 29, 2015 | B | VIOLATION CLOSED | 1C | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH |
| Dec 29, 2015 | B | VIOLATION CLOSED | 1C | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILINGS * IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH |
| Dec 29, 2015 | B | VIOLATION CLOSED | 1C | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT PANTRY CLOSET SOUTH WALL IN THE KITCHEN LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH |
| Dec 29, 2015 | A | VIOLATION CLOSED | 1C | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION PANTRY CLOSET CREATED IN DUMBWAITER SHAFT* IN THE KITCHEN LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH |
| Dec 29, 2015 | B | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE VOICE AND RETURN BUZZER SYSTEM FROM 1STORY PUBLIC HALL TO FOYER * LOCATED AT APT 2F, 2nd STORY, APARTMENT AT NORTH , SECTION AT NORTH |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING RETURN RAIL 1ST STORY BALCONY AT EAST/NORTH FRONT ** AT FIRE ESCAPE |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING RETURN RAIL 1ST STORY BALCONY AT EAST/SOUTH FRONT * AT FIRE ESCAPE |
| Dec 29, 2015 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LOCK AND LATCH SET AT THE BUILDING ENTRANCE DOOR , 1st STORY |
| Dec 29, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT THE BUILDING ENTRANCE DOOR , 1st STORY |
| Dec 29, 2015 | B | VIOLATION CLOSED | EE | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE .. IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT EE, 1st STORY, APARTMENT AT EAST |
| Dec 29, 2015 | C | VIOLATION CLOSED | EE | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH LOCATED AT APT EE, 1st STORY, APARTMENT AT EAST |
| Dec 29, 2015 | A | VIOLATION CLOSED | 2H | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION SHEETROCK AT DROP CEILING IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Dec 29, 2015 | C | VIOLATION CLOSED | 2H | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Dec 29, 2015 | A | VIOLATION CLOSED | 2H | § 27-2005 ADM CODE REFIT DOOR IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Dec 29, 2015 | B | VIOLATION CLOSED | 2H | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Dec 29, 2015 | B | VIOLATION CLOSED | 2H | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASHBASIN * IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Dec 29, 2015 | A | VIOLATION CLOSED | 2H | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD PANELS INSTALLED AT ALL WALLS * IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Dec 29, 2015 | C | VIOLATION CLOSED | 2H | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE FOYER LOCATED AT APT 2H, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Dec 29, 2015 | C | VIOLATION CLOSED | 2H | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2H, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |