Date Status Type Summary
Jun 24, 2026 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AS PER SECTION 28.301.1 OF THE NYC ADMIN CODE.NOTED AT TIME OF INSPECTION,OBSERVED NU MEROUS VERTICAL CRACKS AT EXPOSURE 1 AND 2.AT ROOF ELEVATION,STEP CRAC KS AND SPALLING ON PARAPET WALLS.REMEDY:REPAIR AND/OR REPLACE
Nov 28, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTC W/COMMISSIONER'S ORDER CONTROL#348341 VIO#102325PI20405SB DATED 10/23/25 REQUIRING OWNER TO PROVIDE A CORRECTIVE ACTION PLAN BY 10/30/25. AS OF TODAY 11/28/2025 A CAP WAS NOT REC'D. IMMED COMPLY W/COMMISSIONER'S ORDER CONTROL#348341 VIO#102325PI20405SB TO PROVIDE A CORRECTIVE ACTION PLAN
Oct 23, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL CORRECTIVE ACTION PLAN REQ'D-OBSVD @ EXP1 MULT MASONRY STEP CRACKS @ THE PARAPET INCL THE COURTYRD AREAS. AT EXP2 OBSVD DETERIORARED MORTAR JOINTS & MASONRY CRACK UNDER 1FL WINDOW @ EXP3 OBSVD SPALLING BRICKS NEAR PARAPET. OWNER TO IMMED RETAIN REG DESIGN PROF TO EVAL ENTIRE BLDG & SUBMIT A CORRECTIVE ACTION PLAN BY 10/30/25
Oct 23, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM BLDG IN A CODE COMPLIANT MANNER-ANNUAL PARAPET OBSERVATION REPORT- OBSVD MASONRY STEP CRACKS @ EXTERIOR PARAPET OF EXP1 ON ROOF.OBSVD PARAPETS @ EXP1&2 IN DISREPAIR,LEANING INWARDS W/MULT DETERIORATED MORTAR.AN ANNUAL PARAPET OBSERV REPORT T/BE COMPL ANNUALLY START 2024 SUBMIT ANNUAL OBSV REPT FOR 2024 T/BE REC'D BY DOB NO LTR THAN 11/6/24
Oct 3, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AS NOTED AT TIME OF INSPECTION,I OBSERVED ON EXP1,2,3,4 CRACKS,STEP CRACKS,SPALLING AT MULTIPLE FLOORS AND LOCATIONS.ALSO OBSERVED ON THESE ELEV WERE SAGGING CORRODED METAL LINTELS,OPEN MORTAR JOINTS,DAMAGED SPALLED EYEBROW WIND OW SILLS.ROOF:CRACKED BRICK & STUCCO ON PARAPET WALL.REPAIR OR REPLACE
Jun 23, 2024 V-DOB VIOLATION - ACTIVE EARCX-FAILURE TO SUBMIT EER NONE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2023
Oct 4, 2023 V-DOB VIOLATION - ACTIVE AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Oct 4, 2023 V-DOB VIOLATION - ACTIVE AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Nov 24, 2021 V-DOB VIOLATION - ACTIVE AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Nov 24, 2021 V-DOB VIOLATION - ACTIVE AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Sep 7, 2021 V*-DOB VIOLATION - DISMISSED IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL INSTALL AN APPROX. TOAL OF 135 LINEAR FEET OF SIDEWALK SHED ALONG THE GRAND CONCOURSE EXPOSURE TO SAFEGUARD THE PUBLIC AND PROPERTY
Sep 5, 2021 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL PARPET LEVEL WITH MULTIPLE CRACKS -MISSING MORTAR-OUT OF PLUMB AT FRON T EXPOSURE GRAND CONCOURSE & LEFT SIDE-TUDOR PLACE REQUEST FOR ENGINEE RS REPORT ON ENTIRE FACADE -SUBMIT TO ERT INSPECTION@BUILINGS.NYC.GOV WITHIN 72 HOURS CALL 718-286-3460
Feb 16, 2017 V*-DOB VIOLATION - DISMISSED EARCX-FAILURE TO SUBMIT EER NONE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2016)
Jun 1, 2016 V*-DOB VIOLATION - DISMISSED EARCX-FAILURE TO SUBMIT EER NONE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS(2015)
Jun 1, 2015 V*-DOB VIOLATION - DISMISSED EARCX-FAILURE TO SUBMIT EER NONE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS
Dec 31, 2013 V*-DOB VIOLATION - DISMISSED EARCX-FAILURE TO SUBMIT EER NONE FAILURE TO SUBMIT AN ENERGY EFFICIENCY REPORT (EER) PER AD. CODE SEC. 28-308.4
Mar 1, 2013 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
May 3, 2012 V-DOB VIOLATION - ACTIVE BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Dec 13, 2011 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
Dec 31, 2009 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
Jan 1, 2009 V-DOB VIOLATION - ACTIVE LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Jan 3, 2008 V-DOB VIOLATION - ACTIVE LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Jan 19, 2007 V-DOB VIOLATION - ACTIVE LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED