Bronx Concourse-Concourse Village
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
23 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Jun 24, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AS PER SECTION 28.301.1 OF THE NYC ADMIN CODE.NOTED AT TIME OF INSPECTION,OBSERVED NU MEROUS VERTICAL CRACKS AT EXPOSURE 1 AND 2.AT ROOF ELEVATION,STEP CRAC KS AND SPALLING ON PARAPET WALLS.REMEDY:REPAIR AND/OR REPLACE |
| Nov 28, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FTC W/COMMISSIONER'S ORDER CONTROL#348341 VIO#102325PI20405SB DATED 10/23/25 REQUIRING OWNER TO PROVIDE A CORRECTIVE ACTION PLAN BY 10/30/25. AS OF TODAY 11/28/2025 A CAP WAS NOT REC'D. IMMED COMPLY W/COMMISSIONER'S ORDER CONTROL#348341 VIO#102325PI20405SB TO PROVIDE A CORRECTIVE ACTION PLAN |
| Oct 23, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | CORRECTIVE ACTION PLAN REQ'D-OBSVD @ EXP1 MULT MASONRY STEP CRACKS @ THE PARAPET INCL THE COURTYRD AREAS. AT EXP2 OBSVD DETERIORARED MORTAR JOINTS & MASONRY CRACK UNDER 1FL WINDOW @ EXP3 OBSVD SPALLING BRICKS NEAR PARAPET. OWNER TO IMMED RETAIN REG DESIGN PROF TO EVAL ENTIRE BLDG & SUBMIT A CORRECTIVE ACTION PLAN BY 10/30/25 |
| Oct 23, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FTM BLDG IN A CODE COMPLIANT MANNER-ANNUAL PARAPET OBSERVATION REPORT- OBSVD MASONRY STEP CRACKS @ EXTERIOR PARAPET OF EXP1 ON ROOF.OBSVD PARAPETS @ EXP1&2 IN DISREPAIR,LEANING INWARDS W/MULT DETERIORATED MORTAR.AN ANNUAL PARAPET OBSERV REPORT T/BE COMPL ANNUALLY START 2024 SUBMIT ANNUAL OBSV REPT FOR 2024 T/BE REC'D BY DOB NO LTR THAN 11/6/24 |
| Oct 3, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AS NOTED AT TIME OF INSPECTION,I OBSERVED ON EXP1,2,3,4 CRACKS,STEP CRACKS,SPALLING AT MULTIPLE FLOORS AND LOCATIONS.ALSO OBSERVED ON THESE ELEV WERE SAGGING CORRODED METAL LINTELS,OPEN MORTAR JOINTS,DAMAGED SPALLED EYEBROW WIND OW SILLS.ROOF:CRACKED BRICK & STUCCO ON PARAPET WALL.REPAIR OR REPLACE |
| Jun 23, 2024 | V-DOB VIOLATION - ACTIVE | EARCX-FAILURE TO SUBMIT EER NONE | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2023 |
| Oct 4, 2023 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Oct 4, 2023 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Nov 24, 2021 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Nov 24, 2021 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Sep 7, 2021 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | INSTALL AN APPROX. TOAL OF 135 LINEAR FEET OF SIDEWALK SHED ALONG THE GRAND CONCOURSE EXPOSURE TO SAFEGUARD THE PUBLIC AND PROPERTY |
| Sep 5, 2021 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | PARPET LEVEL WITH MULTIPLE CRACKS -MISSING MORTAR-OUT OF PLUMB AT FRON T EXPOSURE GRAND CONCOURSE & LEFT SIDE-TUDOR PLACE REQUEST FOR ENGINEE RS REPORT ON ENTIRE FACADE -SUBMIT TO ERT INSPECTION@BUILINGS.NYC.GOV WITHIN 72 HOURS CALL 718-286-3460 |
| Feb 16, 2017 | V*-DOB VIOLATION - DISMISSED | EARCX-FAILURE TO SUBMIT EER NONE | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2016) |
| Jun 1, 2016 | V*-DOB VIOLATION - DISMISSED | EARCX-FAILURE TO SUBMIT EER NONE | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS(2015) |
| Jun 1, 2015 | V*-DOB VIOLATION - DISMISSED | EARCX-FAILURE TO SUBMIT EER NONE | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS |
| Dec 31, 2013 | V*-DOB VIOLATION - DISMISSED | EARCX-FAILURE TO SUBMIT EER NONE | FAILURE TO SUBMIT AN ENERGY EFFICIENCY REPORT (EER) PER AD. CODE SEC. 28-308.4 |
| Mar 1, 2013 | V-DOB VIOLATION - ACTIVE | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT |
| May 3, 2012 | V-DOB VIOLATION - ACTIVE | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Dec 13, 2011 | V-DOB VIOLATION - ACTIVE | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT |
| Dec 31, 2009 | V-DOB VIOLATION - ACTIVE | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED |
| Jan 1, 2009 | V-DOB VIOLATION - ACTIVE | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jan 3, 2008 | V-DOB VIOLATION - ACTIVE | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jan 19, 2007 | V-DOB VIOLATION - ACTIVE | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |