NYC Building Report

Bronx Concourse-Concourse Village

1018-1020 Walton Ave, Bronx

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

23 records

Date Status Type Summary
Jul 7, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK ORDER DUE TO CRACKED/BULGING BRICK EXP2 NORTH COURTYARD ABOVE BASEMENT ENTRY @ 2FL & CRACKED DISPACED BRICK BENEATH 6FL FIRE ESCAPE @ EXP3 EAST COURTYARD. REMEDY:IMMEDIATELY TAKE/PROVIDE ADEQUATE SAFETY MEASURES SECURE/PROTECT THE PUBLIC. ALSO REMOVE/SECURE ANY & ALL LOOSE MATERIALS U/SUPERVISION OF NYS LICENSED PROFESSIONAL
Apr 26, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL PARTIAL VACATE ORDER DUE TO MULTIPLE HAZARDOUS CONDITIONS SUCH AS CRAC KED MASONRY BRICKS,CRACKED ROOF PARAPET AND DETERIORATED WINDOW SILLS THESE CONDITIONS HAVE THEREFORE MADE THE COURTYARDS AT EXP2 NORTH,3 EA ST AND 4 SOUTH UNABLE TO BE OCCUPIED.REMEDY:VACATE ENTIRE COURTYARD AT EXP2 NORTH,3 EAST,AND 4 SOUTH.ONLY TO BE USED IN EMERGENCIES ONLY
Apr 22, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK ORDER 4/22/24 DUE TO DEFECTIVE FACADE.NOTE MULTIPLE UNS AFE CONDITIONS OBSERVED AT EXP1 WEST ELEV.MULTIPLE CRACKED BRICKS2)LOO SE BRICKS AT 3RD AND 4TH STORY WINDOWS.3)BRICKS DISPLAYING SIGNS OF MO VEMENT,BULDGING AT ROOF LEVEL.4)VERTICAL CRACK AT PARAPET CORNER.REMED Y:PROVIDE SAFETY MEASURES & INSTALL SWS AT EXP1 WEST ELEV WALTON AVE
Jun 30, 2023 V*-DOB VIOLATION - DISMISSED LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Nov 2, 2021 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Aug 15, 2019 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Jun 28, 2017 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Apr 13, 2015 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
May 15, 2014 V*-DOB VIOLATION - DISMISSED LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Dec 27, 2013 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Jan 30, 2012 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Feb 18, 2011 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Mar 12, 2008 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Jul 24, 2007 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Nov 8, 2006 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Jan 31, 2006 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
May 23, 2005 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Oct 27, 2004 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Oct 28, 2003 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Feb 14, 2002 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Nov 24, 1999 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED 2P725
Oct 16, 1989 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED (18)REPAIR GREENFIELD TO INTERLOCKS WHERE NECESSARY (74A)CLEAN CAR TOP (15)REPLACE BROKEN VISION GLASS WHERE NECESSARY (15)PROVIDE HOISTWAY DOOR HANDLES WHERE NECESSARY
Oct 17, 1988 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED (15)SECURE (35)COVERS (50)MOTOR ROOM (51)CLEAN TOP OF CAR & PROVIDE LIGHT TOP OF CAR